Mise à niveau au codeur incrémental TONiC・Cette page n'est pas disponible actuellement dans votre langue. Vous pouvez en afficher une traduction automatique avec l'outil Google Translate. Cependant nous déclinons toute responsabilité quant à ce service et nous ne contrôlons pas les résultats de la traduction. Have you tried the new TONiC encoder yet? Here are 5 compelling reasons why Renishaw’s super-compact readhead should feature on your next rotary or linear motion axis! Have you tried the new TONiC encoder yet? Listen to 5 compelling reasons why Renishaw's super-compact readhead should feature on your next rotary or linear motion axis! Read on for a further details and click on the graphs to see TONiC's outstanding performance results! Reason 1: Smaller size meets higher reliability
High dirt immunity is just the first of many aspects of reliability that have been designed into TONiC. For example, unlike many other competitor encoders, TONiC readheads are fitted as standard with cables featuring double shielding (braid, not foil) for dependable use in the most demanding EMI environments even under highly dynamic flex conditions. Another example is the IR light source; TONiC uses a custom LED made using a specially-selected die with mean time to failure (MTTF) of 231 million hours, because failure in service just isn't an option. Now there's no need to compromise. TONiC's compact dimensions of 35 x 13.5 x 10 mm are amongst the smallest on the market, even with all that quality and reliability built in. Click on image to see the lastest generation filtering optics. Reason 2: Higher accuracy
Click on image to see "RSLM error plot, showing ±0.67 µm total accuracy over 3 metres".
For applications requiring high accuracy combined with easily removable scale, combine TONiC with FASTRACK™, a revolutionary track-mounted linear encoder scale system from Renishaw that combines ±5 µm/m accuracy, with the ruggedness of stainless steel, and the quick and easy installation of a carrier-type encoder system. Furthermore, FASTRACK allows the precisely-graduated RTLC incremental scale to maintain its own CTE with almost zero hysteresis for outstanding metrology, regardless of substrate material or wide temperature swings.
Click on image to see "FASTRACK system error plot, showing ±16.2 µm total accuracy over 3.4 metres".
High accuracy angle encoders are also available within the TONiC family, the pinnacle of which is the REXM encoder, offering total installed accuracy guaranteed better than ±1 arc second when used with dual TONiC readheads. Connecting the dual readheads to industry-standard controllers is now easy, thanks to the new TONiC DSi (Dual Signal Interface), which combines the incremental signals to appear to the controller like a single high-accuracy encoder. DSi also adds Renishaw's patented propoZ™ technology for a perfectly repeatable reference position, regardless of bearing wander and cycling of power.
Click on image to see "REXM error plot, showing ±0.22 arc second total installed accuracy".
Reason 3: Superior motion controlAll TONiC readheads include dynamic signal processing including Auto Offset Control and Auto Gain Control to achieve very low Sub-Divisional Error (SDE) down to typically ±30 nm. TONiC is now also available with resolutions to 1 nm, whilst ultra-low noise opto-electronics design and new Ti20KD interface provide jitter to 0.51 nm RMS. Using TONiC can help realise superior motion control performance:
Click on graphs to enlarge
Reason 4: Higher speedWant to go faster? TONiC offers maximum speeds up to 10 m/s. Most importantly, Renishaw's advanced interpolation electronics enable optimised speed capability for all users, by providing outputs clocked to match industry-standard controllers. Even fine resolution versions can achieve surprisingly high speeds… and give your machine a valuable edge over the competition.
Note: Chart refers to TONiC Ti interfaces for 50 MHz recommended counter clock frequency. For speeds of TONiC Ti interfaces for other counter clock frequencies, please refer to TONiC data sheets. Reason 5: Quicker and easier installation
Installing a TONiC readhead couldn't be simpler… a set-up LED on the readhead gives an intuitive visual indication to show when good signal level has been achieved, eliminating the need for additional diagnostic tools and reducing the chance of human error. Wide set-up tolerances make that adjustment effortless. Once a green set-up LED has been achieved, simply press the CAL button on the TONiC interface and let the encoder's intelligent technology take over… a two-step operation automatically sets the incremental signal to the ideal 1 Vpp level and then sets the phasing of the IN-TRAC™ optical reference mark for guaranteed bi-directional unit-of-resolution repeatability of the index position. Finally, press-and-hold the CAL button to enable dynamic signal processing (Auto Gain Control and Auto Offset Control), to help maintain optimum signal condition in subsequent operation. Click on the image to watch the TONiC installation video Find out more information about TONiC optical incremental encoders Brochures
Data sheets
Installation guides
News
Videos
3D Models